Flash radiography: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Howard C. Berkowitz
No edit summary
imported>Howard C. Berkowitz
No edit summary
Line 76: Line 76:
  | author = Katie Walker
  | author = Katie Walker
  | date = May 1997}}</ref></blockquote>
  | date = May 1997}}</ref></blockquote>
One state-of-the-art facility is the Dual-Axis Radiographic Hydrodynamic Test (DARHT) at [[Los Alamos National Laboratory]], which, by imaging simultaneously with beams at right angles, gives a much better three-dimensional sense of the target.  Its first full test was on 9 December 2009.<ref>{{citation
| title = NNSA, LANL Announce Successful First Dual-Axis Hydrodynamic Test
| publisher = [[Los Alamos National Laboratory]]
| url = http://www.lanl.gov/news/releases/nnsa_lanl_announce_successful_first_dual_axis_hydrodynamic_test_nr.html}}</ref>  It uses two linear accelerators:
*Phase 1:  short pulse single shot accelerator using ferrite induction cells.
*Phase 2: long pulse linac using Metglas induction cells.
The beam at the exit of the accelerator is required to be 2 kA of electrons at 20 MeV and with a 2 μs long flat current pulse. Downstream kicker systems being designed and built by Lawrence Livermore National Laboratory (LLNL) will select 4 short pulses out of the 2 μs macropulse for delivery to the X-ray conversion target."<ref>{{citation
| url = http://cdsweb.cern.ch/record/453403/files/0008156.pdf
| title = The DARHT Phase 2 LINAC
| author = H. L. Rutkowski ''et al.''}}</ref>
==Proton beam==
==Proton beam==
Proton radiography (pRad) utilizes conventional high energy accelerator technology to provide bursts of higher kinetic energy (1–50 GeV) protons distributed uniformly across objects to create flash radiographs of equivalent mass-profile information to the best flash X-ray radiographs
Proton radiography (pRad) utilizes conventional high energy accelerator technology to provide bursts of higher kinetic energy (1–50 GeV) protons distributed uniformly across objects to create flash radiographs of equivalent mass-profile information to the best flash X-ray radiographs
For appropriate applications, the newer pRad technology offers advantages over X-ray.  First, it can image more quickly than a comparable X-ray facility, 20 versus 4 in a single hydrotest. This allows approximation of full motion.
Second, pRad better distinguishes between different densities in its subject, being able, which X-ray cannot, of determining if a glass of water is full or half full. Imaging of density requires measuring the attenuation of the signal within the object; the ''attenuation length'' should be reached at approximately half the thickness of the object. "The attenuation length is the distance in which the intensity of a proton beam decreases to about a third of its initial value as the beam passes through the test object. If the attenuation length is much shorter than the object's thickness, the protons will not penetrate the object, and the resulting radiograph will show a silhouette of the object but nothing inside it. If the attenuation length is much greater than this thickness, all the protons will sail through the object, leaving no trace of it in the radiograph. The optimum attenuation length is between these two extremes."
"For most elements in the periodic table, a proton's attenuation length increases with its energy. Fortunately, modern accelerators can produce protons with the high energies required to match their attenuation lengths to the thickness of a hydrotest mock-up. The attenuation lengths for x-rays, however, peak at about 4 million [[electronvolt]]s, the reason that DARHT produces x-rays with this energy. But even at its peak, the x-ray attenuation length is only a tenth or less that of high-energy protons, the main reason that proton radiographs of thick, dense hydrotest objects reveal much smaller changes in density than is possible with x-rays.
"The longer attenuation lengths of high-energy protons also allow a much larger fraction of the protons to pass through the test object than is possible with x-rays, while still producing radiographs that detect small changes in density. Thus, the total amount of radiation, or dose, required to produce a proton radiograph is much less than that required for an x-ray radiograph.<ref>{{citation
|  title = Proton Radiography: Sharper "X-rays" for Hydrotests
| url = http://www.lanl.gov/quarterly/q_w03/pro_rad.shtml#experiments
| publisher = [[Los Alamos National Laboratory]]
}}</ref>
==References==
==References==
{{reflist|2}}
{{reflist|2}}

Revision as of 22:41, 17 May 2010

This article is developing and not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This editable Main Article is under development and subject to a disclaimer.

Flash radiography is a technique to photograph objects moving at extremely high speed, such as in explosions, to allow the measurement of "their position, speed, shape, and internal density profiles...radiographic images are used to validate computer models and to experimentally determine material parameters in transient interactions, including high temperature and pressure regimes." While it has dual-use civilian applications, it is a technology critical to the development of nuclear weapons and advanced conventional explosives.

The technique appears to have been invented independently by British and American workers in 1943,[1] and by German researchers whose work was discovered after WWII,[2] and by Soviet engineers in the same time period. All were initially working on shaped charges. British development was under J.L. Tuck at the Armaments Research Department; U.S. work at Aberdeen Proving Ground by L.B. Seely and J.C. Clark; the German development by H. Schardin and E. Schumann;[3] and the Soviet work by L. Altshuler and V. Zukerman.[4]

Any flash radiography system used to image explosions has the main components:

  1. Illumination source (X-rays or protons)
  2. an experimental configuration which contains the blast and debris from dynamic experiments
  3. a high resolution and quantum efficiency detection system to record the radiographic image
  4. analysis software to interpret the image into physically useful information.[5]

X-ray

Lawrence Livermore National Laboratory X-ray flash

There are several ways to produce the X-rays:

Generator technology Energy Notes
Linear induction accelerators (LIAs 20 MeV single pulse, 500 R dose at 1 m in 60 ns from ~ 2-mm spot.
Pulsed power accelerators 14 MeV ~ 100 kA Larger spot than LIA
High intensity laser beams 100 MeV order of ten micron spot size

A computer-aided design layout shows placement of the experiment, which is surrounded by mirrors on stands, flashlamps, and a radiographic film cassette. Extremely energetic x rays emerge from the Flash X Ray machine through a port (upper right). Behind the experiment is the protective enclosure for radiographic film. Images from a series of mirrors are reflected to four optical cameras, providing different viewpoints. Each optical path is indicated by a different color. The cameras are located directly below the four ports on the left.[6]

In the late 1990s, the flash source at Lawrence Livermore National Laboratory was a induction linear accelerator. A gamma ray camera, rather than traditional X-ray film, captures the image.

An injector introduces an electron beam into the FXR accelerator. After passing through the accelerator, the beam enters a drift section that directs it toward a 1-millimeter-thick strip of tantalum, called a target. As the high-energy electrons pass through the target, the electric field created by the stationary charged particles of the heavy tantalum nuclei causes the electrons to decelerate and radiate some of their energy in the form of x rays. The product of this slowing process is called bremsstrahlung (braking) radiation. The x-ray photons travel toward the exploding device, where most are absorbed. The photons that make it to the camera are the image data.[7]

One state-of-the-art facility is the Dual-Axis Radiographic Hydrodynamic Test (DARHT) at Los Alamos National Laboratory, which, by imaging simultaneously with beams at right angles, gives a much better three-dimensional sense of the target. Its first full test was on 9 December 2009.[8] It uses two linear accelerators:

  • Phase 1: short pulse single shot accelerator using ferrite induction cells.
  • Phase 2: long pulse linac using Metglas induction cells.

The beam at the exit of the accelerator is required to be 2 kA of electrons at 20 MeV and with a 2 μs long flat current pulse. Downstream kicker systems being designed and built by Lawrence Livermore National Laboratory (LLNL) will select 4 short pulses out of the 2 μs macropulse for delivery to the X-ray conversion target."[9]

Proton beam

Proton radiography (pRad) utilizes conventional high energy accelerator technology to provide bursts of higher kinetic energy (1–50 GeV) protons distributed uniformly across objects to create flash radiographs of equivalent mass-profile information to the best flash X-ray radiographs

For appropriate applications, the newer pRad technology offers advantages over X-ray. First, it can image more quickly than a comparable X-ray facility, 20 versus 4 in a single hydrotest. This allows approximation of full motion.

Second, pRad better distinguishes between different densities in its subject, being able, which X-ray cannot, of determining if a glass of water is full or half full. Imaging of density requires measuring the attenuation of the signal within the object; the attenuation length should be reached at approximately half the thickness of the object. "The attenuation length is the distance in which the intensity of a proton beam decreases to about a third of its initial value as the beam passes through the test object. If the attenuation length is much shorter than the object's thickness, the protons will not penetrate the object, and the resulting radiograph will show a silhouette of the object but nothing inside it. If the attenuation length is much greater than this thickness, all the protons will sail through the object, leaving no trace of it in the radiograph. The optimum attenuation length is between these two extremes."

"For most elements in the periodic table, a proton's attenuation length increases with its energy. Fortunately, modern accelerators can produce protons with the high energies required to match their attenuation lengths to the thickness of a hydrotest mock-up. The attenuation lengths for x-rays, however, peak at about 4 million electronvolts, the reason that DARHT produces x-rays with this energy. But even at its peak, the x-ray attenuation length is only a tenth or less that of high-energy protons, the main reason that proton radiographs of thick, dense hydrotest objects reveal much smaller changes in density than is possible with x-rays.

"The longer attenuation lengths of high-energy protons also allow a much larger fraction of the protons to pass through the test object than is possible with x-rays, while still producing radiographs that detect small changes in density. Thus, the total amount of radiation, or dose, required to produce a proton radiograph is much less than that required for an x-ray radiograph.[10]

References

  1. Lillian Hoddeson et al. (2004), Critical Assembly: A Technical History of Los Alamos during the Oppenheimer Years, 1943–1945, Cambridge University Press, p. 448
  2. William Walters (22–26 September 2008), A Brief History of Shaped Charges, vol. 1, 24th International Symposium on Ballistics (reprinted by U.S. Army Research Laboratory), at 3–10
  3. William Walters (1990), The Shaped Charge Concept, Part II: The History of Shaped Charges, U.S. Army Ballistic Research Laboratory
  4. Richard Rhodes (1995), Dark Sun: the Making of the Hydrogen Bomb, Simon & Schuster, ISBN 068480400X, p. 286
  5. Under Secretary of Defense, Acquisition, Technology and Logistics Pentagon, VA (June 2009), Section 15, Nuclear Systems Technology; Section 15.1, Flash Radiography, Militarily Critical Technologies List, U.S. Department of Defense
  6. "Ramrods Shepherd Hydrodynamic Tests", Science and Technology Review, Lawrence Livermore National Laboratory, September 2007
  7. Katie Walker (May 1997), Better Flash Photography using the FXR, Lawrence Livermore National Laboratory
  8. NNSA, LANL Announce Successful First Dual-Axis Hydrodynamic Test, Los Alamos National Laboratory
  9. H. L. Rutkowski et al., The DARHT Phase 2 LINAC
  10. Proton Radiography: Sharper "X-rays" for Hydrotests, Los Alamos National Laboratory