Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>. The jugular venous pulse (JVP) is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis. | Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>. The jugular venous pulse (JVP) is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis. |
Revision as of 05:31, 8 June 2009
In physiology, the central venous pressure is "blood pressure in the central large veins of the body. It is distinguished from peripheral venous pressure which occurs in an extremity."[1] Various disease states such as heart failure raise the central venous pressure.
Detection of elevated central venous pressure
Physical examination
Procedure
Inspection
Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.[2]. The jugular venous pulse (JVP) is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis.
Variations on the usual examination include using the external jugular vein[3] and examining the patient while the patient is sitting erect at 90°.[4]
The JVP is considered abnormal when the meniscus of the pulse is 4 cm above the sternal angle of Louis when the patient is reclining at 45°. When examining the patient sitting upright, the jugular pulse is considered abnormal if it is visualized above the clavicle. When the pulsation is elevated the patient has jugular venous distention (JVD).
Abdominojugular test
The abdominojugular test (AJR) is another method of detecting an abnormal central venous pressure. According to some[5], but not all[6] studies, the AJR is more sensitive than inspection.
Interpretation
The physical examination is more specific than sensitive in detecting an elevated central venous pressure according to a systematic review by the Rational Clinical Examination (RCE).[2]The accuracy of visualizing the meniscus of the jugular pulse at 4 or more centimers above the sternal angle of Louis in the reclining patient according to one study in included in the systematic review by the RCE:[7]
- sensitivity = 48%
- specificity = 88%
If inspecting the patient sitting erect, visualizing the jugular pulse above the clavicle is:[4]
- sensitivity = 77%
- specificity = 68%
References
- ↑ Anonymous (2024), Central venous pressure (English). Medical Subject Headings. U.S. National Library of Medicine.
- ↑ 2.0 2.1 Cook DJ, Simel DL (1996). "The Rational Clinical Examination. Does this patient have abnormal central venous pressure?". JAMA 275 (8): 630–4. DOI:10.1001/jama.275.8.630. PMID 8594245. Research Blogging.
- ↑ Stoelting RK (1973). "Evaluation of external jugular venous pressure as a reflection of right atrial pressure". Anesthesiology 38 (3): 291–4. PMID 4698149. [e]
- ↑ 4.0 4.1 Sinisalo J, Rapola J, Rossinen J, Kupari M (2007). "Simplifying the estimation of jugular venous pressure". Am. J. Cardiol. 100 (12): 1779–81. DOI:10.1016/j.amjcard.2007.07.030. PMID 18082526. Research Blogging.
- ↑ Ewy GA (1988). "The abdominojugular test: technique and hemodynamic correlates". Ann. Intern. Med. 109 (6): 456–60. PMID 3415106. [e]
- ↑ Marantz PR, Kaplan MC, Alderman MH (1990). "Clinical diagnosis of congestive heart failure in patients with acute dyspnea". Chest 97 (4): 776–81. PMID 2182296. [e]
- ↑ Cook DJ (1990). "Clinical assessment of central venous pressure in the critically ill". Am. J. Med. Sci. 299 (3): 175–8. PMID 2316561. [e]